{"created":"2023-06-19T10:27:58.291205+00:00","id":128,"links":{},"metadata":{"_buckets":{"deposit":"fdd02858-cb4a-44f4-838e-b77c2880ceb6"},"_deposit":{"created_by":31,"id":"128","owners":[31],"pid":{"revision_id":0,"type":"depid","value":"128"},"status":"published"},"_oai":{"id":"oai:kwmed.repo.nii.ac.jp:00000128","sets":["1709617079800:37:56:339"]},"author_link":["127328","127329"],"item_1694495855422":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_3_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1984","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"224","bibliographicPageStart":"217","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"Kawasaki medical journal","bibliographic_titleLang":"en"}]}]},"item_3_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Original Article","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_3_identifier_14":{"attribute_name":"URL","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"http://igakkai.kms-igakkai.com/wp/wp-content/uploads/1984en/10(4)217-224.1984.pdf"}]},"item_3_relation_20":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.11482/KMJ-E10(4)217 ","subitem_relation_type_select":"DOI"}}]},"item_3_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA00710169","subitem_source_identifier_type":"NCID"},{"subitem_source_identifier":"AA12029005","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-0234","subitem_source_identifier_type":"PISSN"},{"subitem_source_identifier":"2434-3404","subitem_source_identifier_type":"EISSN"}]},"item_3_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Microbiology, Kawasaki Medical School"},{"subitem_text_language":"en","subitem_text_value":"Department of Microbiology, Kawasaki Medical School"}]},"item_3_textarea_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_textarea_language":"en","subitem_textarea_value":"Antibodies to Chlamydia psittaci in sera of healthy human adults, immunized and nonimmunized animals, rabbits and mice, were assayed by the enzyme-linked immunosorbent assay (ELISA) and then the titers were compared with those assayed by the microplate immunofluorescence antibody technique (MFA). The titers of rabbit and mouse sera determined by these two different methods were virtually identical to each other in both specificity and sensitivity. However, many of the human sera showed nonspecific, false positive reaction in the ELISA test. The results indicated that the MFA was more reliable than the ELISA and that the titers obtained by the ELISA had to be examined by other titration method to confirm the specificity. Such disadvantage was not seen in the MFA for the titration of antichlamydial human sera. "}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"BESSHO, Hiroko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"127328","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MATSUMOTO, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"127329","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-01-23"}],"displaytype":"detail","filename":"KJ00010225299.pdf","filesize":[{"value":"946.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00010225299.pdf","objectType":"fulltext","url":"https://kwmed.repo.nii.ac.jp/record/128/files/KJ00010225299.pdf"},"version_id":"77d7c709-40df-495d-9b68-25917946e428"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"MFA","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ELISA","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Antibody","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Chlamydia psittaci","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Nonspecific reaction","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Detection of Antibody to Chlamydia psittaci: Comparison of Antibody Titers in Human Sera Assayed by Enzyme-linked Immunosorbent Assay (ELISA) and Microplate Immunofluorescence Antibody Technique (MFA)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Detection of Antibody to Chlamydia psittaci: Comparison of Antibody Titers in Human Sera Assayed by Enzyme-linked Immunosorbent Assay (ELISA) and Microplate Immunofluorescence Antibody Technique (MFA)","subitem_title_language":"en"}]},"item_type_id":"3","owner":"31","path":["339"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-01-23"},"publish_date":"2017-01-23","publish_status":"0","recid":"128","relation_version_is_last":true,"title":["Detection of Antibody to Chlamydia psittaci: Comparison of Antibody Titers in Human Sera Assayed by Enzyme-linked Immunosorbent Assay (ELISA) and Microplate Immunofluorescence Antibody Technique (MFA)"],"weko_creator_id":"31","weko_shared_id":-1},"updated":"2024-06-10T07:38:25.734671+00:00"}