WEKO3
アイテム
Evaluation of the appropriate reaming diameter during initial fixation of a cementless hip prosthesis
https://kwmed.repo.nii.ac.jp/records/3051
https://kwmed.repo.nii.ac.jp/records/305131a33bb0-adec-4cc8-89a7-a5e71d25a990
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2023-03-10 | |||||||||||||||
タイトル | ||||||||||||||||
タイトル | Evaluation of the appropriate reaming diameter during initial fixation of a cementless hip prosthesis | |||||||||||||||
言語 | en | |||||||||||||||
言語 | ||||||||||||||||
言語 | eng | |||||||||||||||
資源タイプ | ||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||
資源タイプ | journal article | |||||||||||||||
著者 |
KIKUOKA, Ryosuke
× KIKUOKA, Ryosuke
× NAMBA Yoshifumi
× MITANI, Shigeru
× KAWAMOTO, Toyohiro
× FURUICHI, Shuro \n
|
|||||||||||||||
著者所属(英) | ||||||||||||||||
言語 | en | |||||||||||||||
値 | Department of Bone and Joint Surgery, Kawasaki Medical School | |||||||||||||||
著者所属(英) | ||||||||||||||||
言語 | en | |||||||||||||||
値 | Department of Bone and Joint Surgery, Kawasaki Medical School | |||||||||||||||
著者所属(英) | ||||||||||||||||
言語 | en | |||||||||||||||
値 | Department of Bone and Joint Surgery, Kawasaki Medical School | |||||||||||||||
著者所属(英) | ||||||||||||||||
言語 | en | |||||||||||||||
値 | Department of Bone and Joint Surgery, Kawasaki Medical School | |||||||||||||||
著者所属(英) | ||||||||||||||||
言語 | en | |||||||||||||||
値 | Department of Bone and Joint Surgery, Kawasaki Medical School | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | Cementless cup | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | Pressfit | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | Under reaming | |||||||||||||||
抄録(英) | ||||||||||||||||
言語 | en | |||||||||||||||
値 | Background: Press-fit fixation is important technical factor to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, appropriate reaming diameter during initial fixation is unclear. Therefore, this study aimed to evaluate the optimal reaming diameter using simulated bones and cementless cups. Methods: Three types of simulated bones with different degrees of hardness were used (10 pcf, 20 pcf, 30 pcf, pcf = 16.02 kg/㎥). Acetabular models were created by reaming the simulated bone into a hemisphere, and the reaming diameters were 48 mm, 49 mm, and 50 mm.The 50 mm diameter acetabular cup was fixed to simulated bones with a compressive load of 16,000 N at a rate of 12 mm/min. The testing machine was attached to a cup fixed to the simulated bone, and a pull-out test, rotation test, and lever-out test were performed. To evaluate the initial gap, ink was applied to the cup surface during the pull-out test, and the contact between the bone and cup was visually evaluated after pull-out. Results: The pull-out load of the 20 and 30 pcf simulated bones was significantly lower at a reaming diameter of 50 mm that those at reaming diameters of both 48 and 49 mm (P < 0.05). The rotational torque of the 20 and 30 pcf simulated bones was significantly lower at a reaming diameter of 50 mm that those at reaming diameters of both 48 mm and 49 mm (P < 0.05). The lever-out moment of the 20 and 30 pcf simulated bones was significantly lower at a reaming diameter of 50 mm than those at reaming diameters of both 48 mm and 49 mm (P < 0.05). Contact between the 30 pcf simulated bone and the cup at a reaming diameter of 48 mm was mainly at the edge of the cup; contact at the center of the cup was poor. Conclusions: We performed mechanical tests using simulated bones and evaluated the initial fixation of the cup according to the bone reaming diameter. We recommend under-reaming by 1 mm in all cases to optimize both initial fixation capacity and contact between acetabular cup and bone. |
|||||||||||||||
書誌情報 |
en : Kawasaki medical journal 巻 48, p. 25-31, 発行日 2022 |
|||||||||||||||
出版者 | ||||||||||||||||
出版者 | Kawasaki Medical Society | |||||||||||||||
ISSN | ||||||||||||||||
収録物識別子タイプ | EISSN | |||||||||||||||
収録物識別子 | 24343404 | |||||||||||||||
書誌レコードID | ||||||||||||||||
収録物識別子タイプ | NCID | |||||||||||||||
収録物識別子 | AA12029005 | |||||||||||||||
DOI | ||||||||||||||||
関連タイプ | isIdenticalTo | |||||||||||||||
識別子タイプ | DOI | |||||||||||||||
関連識別子 | https://doi.org/10.11482/KMJ-E202248025 | |||||||||||||||
記事種別(英) | ||||||||||||||||
内容記述 | Regular Article | |||||||||||||||
言語 | en | |||||||||||||||
関連サイト | ||||||||||||||||
識別子タイプ | URI | |||||||||||||||
関連識別子 | https://igakkai.kms-igakkai.com/wp/wp-content/uploads/2022en/KMJ-E202248025.pdf | |||||||||||||||
著者版フラグ | ||||||||||||||||
出版タイプ | VoR | |||||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |